Mostrar el registro sencillo del objeto digital

dc.contributor.author Pérez Cruz, Jorge Tonatiuh
dc.contributor.author González León, Claudia
dc.contributor.author Mendieta Zerón, Hugo
dc.creator Pérez Cruz, Jorge Tonatiuh;#0000-0003-2037-5267
dc.creator González León, Claudia;x1349398
dc.creator Mendieta Zerón, Hugo; 45175
dc.date.accessioned 2021-08-17T03:04:03Z
dc.date.available 2021-08-17T03:04:03Z
dc.date.issued 2021-06
dc.identifier.issn 2708-8642
dc.identifier.uri http://hdl.handle.net/20.500.11799/110751
dc.description.abstract Background. Ultrasound has led to non-invasive neuromonitoring for surveillance and decision-making of aspects affecting the central nervous system. The aim was to determine the correlation between mean blood pressure and bilateral optic nerve sheath diameter, pulsatility index and mean flow rate of the middle cerebral artery in cases of preeclampsia/eclampsia. Methods. It was a prospective cohort study, including pregnant women diagnosed with preeclampsia/eclampsia who received medical attention in an Intensive Care Unit. The registered ultrasonographic measurements (optic nerve sheath diameter, pulsatility index and mean fl ow rate) were correlated against mean blood pressure at admission and after 24 and 72 hours. The recorded data were entered in an Excel sheet with subsequent use of the Social Science Statistics online web page. Results. The correlation analysis indicated that at admission, mean blood pressure had a significant negative correlation with mean flow rate (right: R2 = -0.52547, p = 0.04426 and left: R2 = -0.63628, p = 0.01077). In relation to optic nerve sheath diameter, the only positive and signifi cant correlation was the one observed with mean blood pressure after 24 hours following admission (R2 = 0.56980, p = 02659). Conclusion. Mean fl ow rate measurements give more consistent and useful information than optic nerve sheath diameter in the hemodynamic evaluation of the preeclamptic women in the first 24 hours. es
dc.language.iso eng es
dc.publisher Proceedings of the Shevchenko Scientific Society. Medical Sciences es
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0
dc.subject Optic nerve sheath diameter es
dc.subject Mean flow rate es
dc.subject Pulsatility index es
dc.subject Preeclampsia es
dc.subject.classification MEDICINA Y CIENCIAS DE LA SALUD es
dc.subject.classification MEDICINA Y CIENCIAS DE LA SALUD
dc.title Optic nerve sheath diameter, mean flow rate, pulsatility index and preeclampsia es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.organismo Medicina es
dc.ambito Estatal es
dc.audience students es
dc.audience researchers es
dc.identificator 3
dc.relation.vol 64
dc.relation.no 1
dc.relation.doi 10.25040/ntsh2021.01.10


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Optic nerve sheath diameter, mean flow rate, pulsatility index and preeclampsia
  • Autor
  • Pérez Cruz, Jorge Tonatiuh
  • González León, Claudia
  • Mendieta Zerón, Hugo
  • Fecha de publicación
  • 2021-06
  • Editor
  • Proceedings of the Shevchenko Scientific Society. Medical Sciences
  • Tipo de documento
  • Artículo
  • Palabras clave
  • Optic nerve sheath diameter
  • Mean flow rate
  • Pulsatility index
  • Preeclampsia
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)