Mostrar el registro sencillo del objeto digital

dc.contributor.author Zagoya López, Joel
dc.contributor.author ZUÑIGA AVILES, LUIS ADRIAN
dc.contributor.author VILCHIS GONZALEZ, ADRIANA HERLINDA
dc.contributor.author AVILA VILCHIS, JUAN CARLOS
dc.creator Zagoya López, Joel;x1356251
dc.creator ZUÑIGA AVILES, LUIS ADRIAN; 212105
dc.creator VILCHIS GONZALEZ, ADRIANA HERLINDA; 121524
dc.creator AVILA VILCHIS, JUAN CARLOS; 59656
dc.date.accessioned 2022-02-16T23:55:25Z
dc.date.available 2022-02-16T23:55:25Z
dc.date.issued 2021-06-17
dc.identifier.issn 2076-3417
dc.identifier.uri http://hdl.handle.net/20.500.11799/112315
dc.description.abstract There are different alternatives when selecting removable prostheses for below the knee amputated patients. The designs of these prostheses vary according to their different functions. These prostheses designs can be classified into Energy Storing and Return (ESAR), Controlled Energy Storing and Return (CESR), active, and hybrid. This paper aims to identify the state of the art related to the design of these prostheses of which ESAR prostheses are grouped into five types, and active and CESR are categorized into four groups. Regarding patent analysis, 324 were analyzed over the last six years. For scientific communications, a bibliometric analysis was performed using 104 scientific reports from the Web of Science in the same period. The results show a tendency of ESAR prostheses designs for patents (68%) and active prostheses designs for scientific documentation (40%). es
dc.description.sponsorship Beca Conacyt Doctorado es
dc.language.iso eng es
dc.publisher Applied Sciences es
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0 es
dc.subject ankle prosthesis; prosthetic foot; lower limb rehabilitation; below-knee amputee es
dc.subject.classification INGENIERÍA Y TECNOLOGÍA es
dc.title Foot/Ankle Prostheses Design Approach Based on Scientometric and Patentometric Analyses es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.organismo Ingeniería es
dc.ambito Nacional es
dc.cve.CenCos 20501 es
dc.type.conacyt article
dc.identificator 7
dc.relation.vol 11
dc.relation.año 2021
dc.relation.no 12
dc.relation.doi https://doi.org/10.3390/app11125591


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Foot/Ankle Prostheses Design Approach Based on Scientometric and Patentometric Analyses
  • Autor
  • Zagoya López, Joel
  • ZUÑIGA AVILES, LUIS ADRIAN
  • VILCHIS GONZALEZ, ADRIANA HERLINDA
  • AVILA VILCHIS, JUAN CARLOS
  • Fecha de publicación
  • 2021-06-17
  • Editor
  • Applied Sciences
  • Tipo de documento
  • Artículo
  • Palabras clave
  • ankle prosthesis; prosthetic foot; lower limb rehabilitation; below-knee amputee
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)

Mostrar el registro sencillo del objeto digital

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe cómo openAccess