Mostrar el registro sencillo del objeto digital

dc.contributor.author Salmerón Valdés, Elias Nahum
dc.contributor.author BURGOS ARCEGA, NESTOR ABUNDIO
dc.contributor.author Scougall Vilchis, Rogelio José
dc.contributor.author MORALES VALENZUELA, ADRIANA ALEJANDRA
dc.contributor.author HEGAZY HASSAN MOUSTAFA, WAEL
dc.contributor.author Lara Carrillo, Edith
dc.contributor.author TORAL RIZO, VICTOR HUGO
dc.contributor.author VELAZQUEZ-ENRIQUEZ, ULISES
dc.creator Salmerón Valdés, Elias Nahum; 370804
dc.creator BURGOS ARCEGA, NESTOR ABUNDIO; 703834
dc.creator Scougall Vilchis, Rogelio José ; 261455
dc.creator MORALES VALENZUELA, ADRIANA ALEJANDRA; 257053
dc.creator HEGAZY HASSAN MOUSTAFA, WAEL; 518232
dc.creator Lara Carrillo, Edith; 226623
dc.creator TORAL RIZO, VICTOR HUGO; 793208
dc.creator VELAZQUEZ-ENRIQUEZ, ULISES;#0000-0002-8796-7809
dc.date.accessioned 2022-10-13T01:32:14Z
dc.date.available 2022-10-13T01:32:14Z
dc.date.issued 2022-06-16
dc.identifier.issn 2076-3417
dc.identifier.uri http://hdl.handle.net/20.500.11799/136969
dc.description.abstract The discrepancy index evaluates the complexity of the initial orthodontic diagnosis. The objective is to compare whether there is a difference in the final discrepancy index score of the American Board of Orthodontics (ABO) when obtained using digital and manual techniques. Fifty-six initial orthodontic records in a digital and physical format were included (28 each) in 2022 at the Center for Research and Advanced Studies in Dentistry. For the digital measurements, iTero and TRIOS 3 intraoral scanners were used, along with Insignia software and cephalometric tracing with Dolphin Imaging software. Manual measurements were obtained in dental casts using the ruler indicated for the previously mentioned discrepancy index, in addition to conventional cephalometric tracing. Student’s t-test did not show statistically significant differences between the digital and manual techniques, with final discrepancy index scores of 24.61 (13.34) and 24.86 (14.14), respectively (p = 0.769). Cohen’s kappa index showed very good agreement between both categorical measure ments (kappa value = 1.00, p = 0.001). The Bland–Altman method demonstrated a good agreement between continuous measurements obtained by both techniques with a bias of 0.2500 (superior limit of agreement =9.0092988, inferior limit of agreement = −8.5092988). Excellent agreement was observed in obtaining the discrepancy index through digital technique (Intraoral scanning and digital records) and manual technique (conventional records). es
dc.language.iso eng es
dc.publisher MDPI es
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by/4.0
dc.subject digital models es
dc.subject cephalometrics es
dc.subject 3D Scanner es
dc.subject bioinformatics es
dc.subject orthodontics es
dc.subject.classification MEDICINA Y CIENCIAS DE LA SALUD
dc.title Agreement of the Discrepancy Index Obtained Using Digital and Manual Techniques—A Comparative Study es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.organismo Odontología es
dc.ambito Internacional es
dc.cve.CenCos 20102 es
dc.cve.progEstudios 648 es
dc.audience students es
dc.audience researchers es
dc.type.conacyt article
dc.identificator 3
dc.relation.vol 12
dc.relation.no 12
dc.relation.doi https:// doi.org/10.3390/app12126105


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Agreement of the Discrepancy Index Obtained Using Digital and Manual Techniques—A Comparative Study
  • Autor
  • Salmerón Valdés, Elias Nahum
  • BURGOS ARCEGA, NESTOR ABUNDIO
  • Scougall Vilchis, Rogelio José
  • MORALES VALENZUELA, ADRIANA ALEJANDRA
  • HEGAZY HASSAN MOUSTAFA, WAEL
  • Lara Carrillo, Edith
  • TORAL RIZO, VICTOR HUGO
  • VELAZQUEZ-ENRIQUEZ, ULISES
  • Fecha de publicación
  • 2022-06-16
  • Editor
  • MDPI
  • Tipo de documento
  • Artículo
  • Palabras clave
  • digital models
  • cephalometrics
  • 3D Scanner
  • bioinformatics
  • orthodontics
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)

Mostrar el registro sencillo del objeto digital

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe cómo openAccess

Buscar en RI


Buscar en RI

Usuario