Mostrar el registro sencillo del objeto digital

dc.contributor.author Gonzalez Reyes, Ximena
dc.contributor.author Mendieta Zerón, Hugo
dc.contributor.author Abarca Castro, Eric Alonso
dc.contributor.author Talavera Peña, Ana Karen
dc.contributor.author Santiago Fuentes, Laura Mercedes
dc.contributor.author Reyes-Lagos, José Javier
dc.date.accessioned 2024-10-12T04:07:46Z
dc.date.available 2024-10-12T04:07:46Z
dc.date.issued 2024-08-29
dc.identifier.issn 1951-6355
dc.identifier.uri http://hdl.handle.net/20.500.11799/141339
dc.description.abstract Breathing rate asymmetry (BRA) refers to the observed disparities in the acceleration and deceleration phases of human respiration. The techniques employed to assess BRA could also be utilized in exploring hypertensive disorders like pre-eclampsia, which is known to cause autonomic cardiorespiratory changes. This study explores features of complexity, including the asymmetry (time irreversibility) of short-term breath-to-breath breathing rate variability among women with severe and moderate pre-eclampsia features compared to those with normal blood pressure. In our study, we retrospectively analyzed continuous respirogram recordings from women in labor, including those diagnosed with severe pre-eclampsia (SP = 22), moderate preeclampsia (P = 19), and normotensive control group (C = 35). Using these data, we calculated 5 min of breath-to-breath (BB) time series to measure Porta’s index (P %), Guzik’s index (G%), and Ehlers’ index (E ), alongside measures of asymmetrical entropy, including the entropy of acceleration runs (HAR), the entropy of deceleration runs (HDR), and total entropy (H). In addition, Fuzzy Entropy (FuzzEn) and Multiscale Fuzzy Entropy (MFE) over timescales 1–20 were calculated from the BB time series. The nonlinearity was assessed by surrogate analysis. The study’s results revealed significant differences in short-term BRA; specifically, mean values of G% and E were the lowest in SP compared to C and P. Conversely, mean values of the HDR were higher in the SP group than the C. Higher mean values of MFE and a greater percentage of nonlinearity were observed in the SP group as compared to the C group. Our results suggest that women with severe pre-eclampsia may exhibit a higher short-term BRA characterized by a lower contribution of breathing rate decelerations to short-term variability, higher irregularity and nonlinearity of BB time series, and particularly more irregular behavior of decelerations compared to normotensive women. This may indicate a potential modification in the autonomic control of breathing rate and breathing instability. es
dc.description.sponsorship Open access funding provided by Universidad Autonoma Metropolitana (BIDIUAM). es
dc.language.iso eng es
dc.publisher THE EUROPEAN PHYSICAL JOURNAL SPECIAL TOPICS es
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0 es
dc.subject Breathing rate asymmetry es
dc.subject Preeclampsia es
dc.subject Normotensive women es
dc.subject.classification MEDICINA Y CIENCIAS DE LA SALUD es
dc.title Comparison of short-term breathing rate asymmetry of preeclamptic and normotensive women in labor es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.ambito Nacional es
dc.validacion.itt No es


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Comparison of short-term breathing rate asymmetry of preeclamptic and normotensive women in labor
  • Autor
  • Gonzalez Reyes, Ximena
  • Mendieta Zerón, Hugo
  • Abarca Castro, Eric Alonso
  • Talavera Peña, Ana Karen
  • Santiago Fuentes, Laura Mercedes
  • Reyes-Lagos, José Javier
  • Fecha de publicación
  • 2024-08-29
  • Editor
  • THE EUROPEAN PHYSICAL JOURNAL SPECIAL TOPICS
  • Tipo de documento
  • Artículo
  • Palabras clave
  • Breathing rate asymmetry
  • Preeclampsia
  • Normotensive women
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)

Mostrar el registro sencillo del objeto digital

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe cómo openAccess

Buscar en RI


Buscar en RI

Usuario

Estadísticas