Mostrar el registro sencillo del objeto digital

dc.contributor.author RODRIGUEZ CHAVEZ, JOSE LUIS
dc.contributor.author Fuentes Gutiérrez, Erika Karina
dc.contributor.author Angeles Vázquez, María de Jesús
dc.contributor.author Mendieta Zerón, Hugo
dc.creator RODRIGUEZ CHAVEZ, JOSE LUIS; 100038
dc.creator Fuentes Gutiérrez, Erika Karina;x1342980
dc.creator Angeles Vázquez, María de Jesús;x1340678
dc.creator Mendieta Zerón, Hugo; 45175
dc.date.accessioned 2018-09-18T00:16:31Z
dc.date.available 2018-09-18T00:16:31Z
dc.date.issued 2018-02-13
dc.identifier.issn 0973-709X
dc.identifier.uri http://hdl.handle.net/20.500.11799/94681
dc.description Plantear la posible utilidad del uso de la tinción de Rojo Congo en el diagnóstico de proteinuria en casos de preeclampsia. es
dc.description.abstract Introduction: Preeclampsia is characterised by the increased excretion of misfolding protein, attracted by a Diazo dye denominated congo red. Aim: To compare congo red staining kit versus a urocolor test to determine proteinuria in patients with preeclampsia. Materials and Methods: This was a prospective, transversal study, performed between August 2010 to July 2011, including pregnant and puerperal women with the clinical diagnosis of preeclampsia. From all patients, a single sample of 24 hours urine was tested with congo red to determine the presence of proteinuria, comparing the qualitative results of the urine dipstick for proteinuria and the gold standard determination of protein in 24 hours urine collection. Differences among nominal conditions were evaluated by the Mann-Whitney U-test. Results: A total of 50 pregnant and puerperal women were included in this study. The statistical comparison between 2 vs. 3, 2 vs. 4 and 3 vs. 4, congo red positive fields reached significant difference (p≤0.001) in relation to the mean proteinuria values for each one. In contrast, with the urocolor test there were no differences per number of positive crosses. Conclusion: The congo red has a high selectivity for beta-folded proteins in preeclampsia being a promising screening test of high value to the clinician. es
dc.language.iso eng es
dc.publisher JCDR Research and Publications (P) Limited. es
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0
dc.subject Congo red es
dc.subject Proteinuria es
dc.subject Preeclampsia es
dc.subject.classification CIENCIAS SOCIALES
dc.title Evaluation of Congo red staining kit to determine proteinuria in preeclampsia es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.organismo Medicina es
dc.ambito Internacional es
dc.cve.CenCos 20201 es
dc.audience students
dc.audience researchers
dc.type.conacyt article
dc.identificator 5


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Evaluation of Congo red staining kit to determine proteinuria in preeclampsia
  • Autor
  • RODRIGUEZ CHAVEZ, JOSE LUIS
  • Fuentes Gutiérrez, Erika Karina
  • Angeles Vázquez, María de Jesús
  • Mendieta Zerón, Hugo
  • Fecha de publicación
  • 2018-02-13
  • Editor
  • JCDR Research and Publications (P) Limited.
  • Tipo de documento
  • Artículo
  • Palabras clave
  • Congo red
  • Proteinuria
  • Preeclampsia
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)

Mostrar el registro sencillo del objeto digital

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe cómo openAccess

Buscar en RI


Buscar en RI

Usuario

Estadísticas