dc.description.abstract The specific and linear energy was calculated in target sizes of 10 µm, 5 µm, 1 µm, 60 nm, 40nm and 20 nm by taking into account the contribution of the primary photon beams and the electrons generated by them in LiF: Mg, Ti (TLD-100). The simulations were carried out by the code PENELOPE 2011. Using different histories of primary particles, for each energy beams the mean deposited energy is the same, but to achieve a statistical deviation lower than 1% the value of 10 was fixed. We find that setting the values C1 = 0.1 C2 = 0.1 and W The Author(s) 2018. This article is published with open access at www.chitkara.edu.in/publications. ISSN No.: 2321-8649(Print) ISSN No.: 2321-9289(Online); Registration No. : CHAENG/2018/51628 cc = W = 50 eV the time of simulation decreases around the 25%. The uncertainties (1 SD) in the specific energy increases with energy for all target sizes and decreases with target size, with values from 1.7 to 94% for 20 nm and between 0.1 and 0.8% for 10 µm. As expected, the specific and linear energies decrease with target size but not in a geometrical behavior. es
dc.language.iso eng es
dc.publisher JOURNAL OF NUCLEAR PHYSICS, MATERIAL SCIENCES, RADIATION AND APPLICATIONS es
dc.relation.ispartofseries VOL 6;1
dc.rights openAccess es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0
dc.subject Specific energy es
dc.subject Linear energy es
dc.subject PENELOPE Code es
dc.subject.classification CIENCIAS SOCIALES
dc.title Effect of the Target Size in the Calculation of the Energy Deposited Using PENELOPE Code es
dc.type Artículo es
dc.provenance Científica es
dc.road Dorada es
dc.organismo Ciencias es
dc.ambito Internacional es
dc.cve.CenCos 21901 es
dc.audience students es
dc.audience researchers es
dc.type.conacyt article
dc.identificator 5


Ficheros en el objeto digital

Este ítem aparece en la(s) siguiente(s) colección(ones)

Visualización del Documento

  • Título
  • Effect of the Target Size in the Calculation of the Energy Deposited Using PENELOPE Code
  • Autor
  • Reyes Romero, Pedro Guillermo
  • Leal Acevedo, Benjamín
  • CASTILLO MEJIA, FERMIN
  • GAMBOA DE BUEN, MARIA ISABEL
  • Fecha de publicación
  • 2018-08-01
  • Editor
  • JOURNAL OF NUCLEAR PHYSICS, MATERIAL SCIENCES, RADIATION AND APPLICATIONS
  • Tipo de documento
  • Artículo
  • Palabras clave
  • Specific energy
  • Linear energy
  • PENELOPE Code
  • Los documentos depositados en el Repositorio Institucional de la Universidad Autónoma del Estado de México se encuentran a disposición en Acceso Abierto bajo la licencia Creative Commons: Atribución-NoComercial-SinDerivar 4.0 Internacional (CC BY-NC-ND 4.0)

Mostrar el registro sencillo del objeto digital

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe cómo openAccess

Buscar en RI


Buscar en RI

Usuario

Estadísticas